Standard & Deluxe Duty Lift Tables Technical Specifications and Accessories
TECHNICAL
A. MECHANICAL:
- Wheel and Dolly Set - A wheel and dolly set is
used for moving empty lifts only and is available on lifts with
minimum length platforms only. (Consult factory on lift &
tilt tables.)
- Caster Wheels - Caster wheels are used for moving
empty or loaded lifts with any size platform. Two wheels are swivel
and two wheels are fixed. Caster wheels can be end mounted or
side mounted which increases the lift lowered height by approximately
5", or they can be mounted under the base frame which increases
the lift lowered height by approximately 7-3/4". (Consult
factory on lift & tilt tables.)
- Bevel Toe Guards - 8" bevel toe guards are
required by OSHA on lifts that are recessed into the floor,
and increase the minimum platform width and length by 8".
The lowered height on lift table models becomes 9". (Consult
factory on lift & tilt and lift & turn tables.)
- End and Side Loading - On lift table models,
reduce the end and side loading capacities by 2% for every inch
added to the standard minimum length or width. Reduce the end
or side loading capacities by 33% if the loads are going to be
rolled onto the platform when the lift is other than fully lowered.
B. ELECTRICAL:
- Standard voltage is 230/60/3. The motor supplied
will operate on 208, 220, 230, 240, 440, 460, 480/60/3.
- While single phase operation is not generally
recommended, 115/60/1 and 230/60/1 motors are available. (Consult
the factory.)
- Due to size constraints, the controller on the
24" travel lift tables can't be mounted under the platform.
C. HYDRAULIC POWER UNITS:
- On deluxe power units, if the frequency of operation
is more than one full lift every: a) 3 minutes on lifts less than
5000 pounds capacity or b) 4 minutes on lifts greater than 5000
pounds capacity, the motors may overheat. Jog lifting must be
limited to one 2 second jog every 10 seconds and not exceed 200
motor starts per hour. Use a high cycle duty power unit if the
frequency of operation exceeds the above.
D. LIFT & TILT:
- The load center of gravity must stay 3-1/2"
inside the platform when fully tilted or the unit may require
special lag down provisions (consult the factory).
- The standard lip return on the tilt table is
1/2" x 8" high x the full platform width.
- Lift and Tilt tables have an external deluxe
power unit.
E. LIFT & TURN:
- Eccentric loading should not exceed 1/2 the load
on 1/2 the platform on platforms up to 48" square, or ¾
of the load on 3/4 of the platform on platforms longer than 48".
- If loads are to be rolled onto the turn table,
corner supports may be required (consult the factory).
- Powered turn tables are non-reversing.
F. EXTRA WIDE LIFT TABLES:
- No further technical information.
G. DOUBLE LONG LIFT TABLES:
- Reduce the end and side loading capacities by
2% for every inch added to the standard minimum length or width,
but end or side loading is never less than 40% of the catalog
rating.
H. DOUBLE WIDE LIFT TABLES:
- Heaviest loads should be rolled over the roller
end of the lift.
I. DOUBLE HIGH LIFT TABLES:
- Lifts must be securely lagged to the floor.
OPTIONAL ACCESSORIES
A. MECHANICAL:
- Any oversize platform without bevel toe guards
- Any size platform with bevel toe guards included
- Wheel and dolly set for minimum length platforms
- Caster wheels
- Locking caster wheels
B. POWER UNITS:
- Standard Duty N/C
- Deluxe (included on Deluxe Duty models) N/C
When substituted for standard power unit
- High cycle
When substituted for standard power unit
When substituted for deluxe power unit
(High cycle power units are external, continuous
running and 3 phase.)
- External air operated power unit with manual
valves.
When substituted for internal standard power unit
When substituted for internal deluxe power unit
- Internal air operated power unit with foot valve
for Standard and Deluxe lift tables. (Up speed = approx. 4 x catalog
speed. Down speed = 1x catalog speed) N/C
C. CUSHIONS:
- Valve cushioned (standard on all units) N/C
- Shock absorbers (standard on deluxe units only)
D. ELECTRICAL:
- Guarded foot switch
- NEMA 4x pendant push button (included in price)
- NEMA 1 wall mount push button
- Up-Down selector switch (key operated)
- Up-Down push button with key lockout
- Limit switch loose
- Limit switch mounted
E. LIFT & TILT:
- Any size platform without bevel toe guards
- Bevel toe guards (consult factory)
F. LIFT & TURN:
- Any size platform without bevel toe guards
N/C
- Bevel toe guards (consult factory)
- Circular turn table add-on
- Limit switch
- Non-powered turn tables:
a. Detent
b. Manual Stop
- Powered turn tables:
a. 7.5 rpm speed N/C
b. Variable speed DC motor (.25 to 7.5 rpm), 115 volts only
G. DOUBLE LONG, DOUBLE WIDE, DOUBLE HIGH:
Any oversize platform without bevel
toe guards
Bevel toe guards
The standard power unit, which is the industry norm for
lift tables, has all the valving built into the pump,
thereby providing the least mass and area for heat
dissipation. |
The deluxe power unit has a separate valve manifold which allows
eight times more heat dissipation for greater endurance and longer
component life. |
The external high cycle power unit with its large oil reservoir
idles continuously to dissipate heat, thereby providing the greatest
endurance for unlimited cycling. |
Shock absorbers reduce any abrupt deceleration that may occur
when a lift fully lowers. |
|