ARCHITECTURAL SPECIFICATIONS
SPECIFICATIONS FOR PIT MOUNTED DOCK LIFTS
(see catalog for model sizes, etc.)
This specification covers an Advance Model ___________ as manufactured by Advance Lifts, Inc. of St. Charles, IL. The lift shall have a ________ lb. lifting capacity with an axle loading capacity of ________ lbs. over the ends and ________ lbs. over the sides, a ________ ft. safety tread steel platform with minimum 8 inch bevel toe guards, a ________ in. lowered height, minimum 58 inch travel and ________ fpm speed. It shall have a ________ HP-230V/60HZ/3PH continuous duty power unit, weatherproof pendant push button control, 20 ft. coil cord for the control, magnetic motor starter and 24-volt control transformer.
Standard platform accessories shall include: |
1. Conformance to OSHA, ANSI, CS202-56, BOCA and NEC.
2. A 10 year structural warranty.
3. Positive mechanical stops within the hydraulic cylinders.
4. A 24-volt, 4 amp fused control circuit.
5. The starter, 3 pole adjustable overloads and 24-volt transformer prewired in a NEMA 12 enclosure with UL approval and label.
|
6. A removable safety maintenance leg.
7. Four heavy-duty torque tubes.
8. An anodized aluminum hydraulic valve manifold.
9. A minimum of 3 in-line hydraulic filters.
10. Minimum 2 inch black and yellow safety markings on the toe guards.
|
11. A minimum 2 inch clearance between the bottom of the toe guard and pit floor when the lift is fully lowered.
12. Lifetime lubricated bearings.
13. Chrome plated axles, shafts and rods.
14. Semi trailer rollover capacity when the lift is fully lowered.
15. A baked-on enamel paint finish.
|
SPECIFICATIONS FOR
SURFACE MOUNTED DOCK LIFTS
(see catalog for model sizes, etc.)
This specification covers an Advance Model ___________ as manufactured by Advance Lifts, Inc. of St. Charles, IL. The lift shall have a ________ lb. lifting capacity with an axle loading capacity of ________ over the ends, a ________ ft. safety tread steel platform with ANSI required 3 inch vertical toe clearance between the platform and the floor when the lift is fully lowered, a ________ in. lowered height, ________ in. travel, ________ in. raised height, ________ fpm speed. It shall have a ________ HP-230V/60HZ/3PH continuous duty power unit, weatherproof pendant push button control, magnetic motor starter and 24-volt control transformer. Standard platform accessories shall include 2 removable hand rails (one on model 1045), a ________ in. hinged steel bridge and ________ in. steel approach ramp.
Minimum design and safety features shall include: |
1. Conformance with OSHA, ANSI, CS202-56, BOCA and NEC.
2. A 10 year structural warranty.
3. Positive mechanical stops within the hydraulic cylinders.
|
4. A 24-volt, 4 amp fused control circuit.
5. The starter, 3 pole adjustable overloads and 24-volt transformer prewired in a NEMA 12 enclosure with UL approval and label.
6. Removable safety maintenance leg(s).
|
7. An anodized aluminum hydraulic valve manifold.
8. Lifetime lubricated bearings.
9. Chrome plated axles, shafts and rods.
10. A baked-on enamel paint finish.
|
Copyright © 2008 Advance Lifts. Inc.